• Falcon 450

    The FALCON 450 series, Micro Vickers, Vickers and Micro Brinell hardness testing machines are a new generation of instruments, improving conventional hardness testing methods and focused on eliminating user influence on the test results. The unique force actuator system utilizes an electronically controlled closed loop system and advanced force sensor technology, with force feedback to achieve absolute accuracy, reliability and repeatability, on each of the forces used for a test. Besides this advanced electromechanical force application system, the FALCON offers superior quality mechanical and optical components, used to complete the instrument.

    Some characteristics:

    - Hardness scales: (Micro-) Vickers, Knoop and Brinell
    - Optical system: Electronic micrometer eyepiece or Analogue eyepiece
    - Objectives: 5x, 10x, 20x, 40x, 60x
    - Motorized turret: Max. 6 positions; 2 indentor positions, 4 objectives positions

    Download PDF

  • Details

    Built-in Camera (Optional)

    Camera for On SCREEN measurements, in combinations with a IMP Impressions™ software system. The camera is protected against dirt and accidental damage or misalignment, by accommodating it inside the head cover.

    Analogue or digital eyepiece

    The Falcon 450 can be standard equip- ped with a digital eyepiece which can be replaced easily by an analogue eyepiece for educational purposes both can also be combined

    Stunning test force range

    Test forces from 10gf up to 62.5kgf, covering Micro Vickers, Vickers and Brinell.

    Super fast 6 positions turret

    Vickers, Knoop or Brinell indenter installed. 2 indenters, 4 objectives

  • Technical Data

    Features:

    Hardness scale

    (Micro-) Vickers, Knoop and Brinell

    Load application

    Multi Load cell, force feedback, closed loop system

    Load range

    10gf up to 62.5kgf

    Motorized turret

    Max. 6 positions; 2 indentor positions, 4 objectives positions

    Optical system

    Electronic micrometer eyepiece or Analogue eyepiece

    Objectives

    5x, 10x, 20x, 40x, 60x

    Overview camera Cam 2

    (Optional) 5Mpx optical ZOOM camera, field of view 50 x 37mm / 200 x 160mm

    Electronic system

    High performance embedded electronics system running ITouch firmware.

    Test loads (depending model)

    10gf, 15gf, 20gf, 25gf, 50gf, 100gf, 200gf, 300gf, 400gf, 1kgf, 2kgf, 2.5kgf, 3kgf, 4kgf, 5kgf, 6.25kgf, 10kgf, 15.625kgf, 20kgf, 25kgf, 30kgf, 31.25kgf, 50kgf, 62.5kgf

    Vickers test range

    HV0.010, HV0.015, HV0.020, HV0.025, HV0.050, HV0.1, HV0.2, HV0.3, HV0.5, HV1, HV2, HV2.5, HV3, HV4, HV5, HV10, HV20, HV25, HV30, HV50

    Brinell test range

    HB1/1kgf, HB1/1.25kgf, HB1/2.5kgf, HB1/5kgf, HB1/10kgf, HB1/30kgf; HB2.5/6.25kgf, HB2.5/7.8125kgf, HB2.5/15.625kgf, HB2.5/31.25kgf, HB2.5/62.5kgf HB5/25kgf, HB5/31.25kgf, HB5/62.5kgf

    Knoop

    HK0.01, HK0.015, HK0.02, HK0.025, HK0.05, HK0.1, HK0.2, HK0.3, HK0.5, HK1, HK2, HK5

    KiC Fracture

    KC/1, KC/3, KC/5, KC/10, KC/15, KC/20, KC/25, KC/50, KC/100, KC/200, KC/300, KC/450

    Indenters

    1 factory certified Vickers indenter included

    Test cycles

    Motorized, automatic procedure

    Standards

    Complies to or exceeds, ISO, ASTM, JIS (Nadcap) standards

    Test force tolerance

    0.5% for all forces

    Display resolution

    0.1 HV, HK, 0.5 HB

    Hardness conversion

    Rockwell, Rockwell Superficial, Vickers, Brinell, Knoop, Leeb & Tensile

    Statistics

    Total test, max, min, average, range, standard deviation, all in real time after each test

    Data storage capacity

    Integrated memory system

    Connectivity

    USB, converter to RS-232, 1 USB for optional integrated CCD camera

    Dwell time setting

    Default 10 seconds, user defined 1 to 99 seconds (1 sec increments)

    Printer

    Optional

    Manual stage dimensions

    Stage 100mm x 100mm,
    Travel 25mm x 25mm,
    Reading 0.01mm

    Motorized stage dimensions

    See optional CNC X-Y stage dimensions in this catalogue

    Operating temperature

    10°C to 35°C, non-condensing

    Humidity

    10% to 90% non-condensing

    Machine dimensions

    525mm x 323mm x 773mm

    Machine weight

    80kg

    Power consumption

    75W

    Power supply

    100VAC to 240VAC, 50/60Hz, single phase